Re-measure a pole from the web

You know which of the three web modes to use, how to check the photo actually uploaded first.

Where: web portal, the pole inspection view.

When you finish: you know which of the three web modes to use, how to check the photo actually uploaded first, and when the honest answer is a fresh capture in the field.

Use this when the inspection view cannot line up a measurement, shows standard placement, or needs a new calibration. A missing measurement line is not proof the photo is gone.


1. Open inspection from the map

  1. Open Utility Map, select the job, then the pole.

  2. Stay on the Data tab.

  3. Choose Measure Utility Pole.

Pole Data tab with the Measure Utility Pole control

Do not use the Photos tab to find the measurement picture; it can say there are none when Data and inspection both show captures. After a fielder syncs a new capture, reopen inspection from the map, not from a saved link.


2. Check the files arrived before you change anything

In inspection, open the History tab and look at Files.

Files says

It means

Do this

Photo and Calibration data present

Healthy

Carry on

Not uploaded by fielder

A file ID exists but the crew never finished sending it

Ask the fielder to open UtilityScout on the job and wait for Synced, then reload inspection

Photo not uploaded by fielder, or Photo upload incomplete on the canvas

Same problem, for the picture itself

Same fix. If still missing after a real sync, send us the object reference


3. Pick the right mode

There is no button labelled Re-measure. Each mode has its own exit; finish the one you open before you leave the page. The page's Save changes can stay disabled while a mode is open.

Mode

Does

Exit

Re-calibrate

Places the scale targets again in four steps: Targets, Tilt, Top/Bottom, Save. A midspan skips Tilt, so it is three steps and the last one is Ground. Put the crosshairs on the target centres, bottom marker on the bottom target, or use Auto-detect first

Save on step 4, or Cancel. Calibrate only finishes step 1

Update pole top and bottom, in Fix measurement

Moves the yellow handles at the pole top and ground line. Re-calibrate and the circumference Measure stay disabled meanwhile

The mode's own Save, or Cancel

Measure (ground line circumference), on the Measure tab

A horizontal measure near the ground line; the overlay shows circumference, diameter, height above ground line and estimated class

Done measuring, which is not a save

Fix measurement, with Re-calibrate ringed.
​

Re-calibrate from start to finish: Targets, Tilt, Top/Bottom, Save.
​

Re-calibrate, step 1 Targets, with Auto-detect ringed.
​

Re-calibrate, step 3 Top/Bottom, then Next (ringed).
​

Re-calibrate, step 4: Save (ringed) finishes the mode.
​

Update Pole Top and Bottom mode with Cancel and Save. Re-calibrate stays disabled.


When the web cannot recover the photo

You see

Cause

Do this

Banner: could not line up the detected pole

Inspection is using standard placement; attachments snap flat to the measure line

Try Reprocess pole once; if nothing usable, a fresh field capture

Re-calibrate disabled, with a tip

AR capture, or no high-accuracy metadata; cannot be re-solved on the web

Fresh field capture

Re-calibrate disabled, no tip

You are in another mode

Come out of it

In the field, the crew selects the pole and uses Re-measure (or Measure if it was never measured). See Measure a pole. Incomplete uploads break exports as well as inspection; see When an export does not finish.


Related